Large commercial project in Connecticut, USA

Photo 18 View of improperly installed metal roof panel, at eave. Improper closure, open to weather, gutter strap torn away from panel by ice.
Photo 19 Gutters at eave torn off roof by ice.
Photo 20

Photo 21

View of panel lap joints at back-up plates and cinch straps. Roof leaks addressed by installation of membrane "coating" placed over lap joints & cinch straps. Notice deterioration of "coating." Damaged and pulled away by water & ice. Coating less than six months old when pictures taken.
Photo 22 Open closure at ridge line of metal roof panel. Notice putty knife placed under metal closure. Indicates unsealed closure.
Photo 23

Photo 24

View of panel lap joints with membrane "coating". There were approximately 525 lap joints on this project. Almost all were sources of water penetration into the building.