View of standing seam metal roof system on medical building project in Florida, USA

View of vertical panels at roof "step up" over auditorium roof. Photos # 32 and 34 show improper "turn down" installation method. This method and installation procedure allows water infiltration into the building. Photo # 38 shows proper "two panel" installation method, using flashings and closures. This represents proper installation procedures.
![]()
[Back]
![]()
Robert Stanford & Associates, Inc.
Metal Roofing Consultants4106 Waterstone Drive
Missouri City, TX 77459-1837
Phone: 281.261.8522
Mobile: 713.202.5468
Website written by Expert Communications, Inc.
Website designed by Anesis Inc.