View of standing seam metal roof system on medical building project in Florida, USA

Photo 38

View of vertical panels at roof "step up" over auditorium roof. Photos # 32 and 34 show improper "turn down" installation method. This method and installation procedure allows water infiltration into the building. Photo # 38 shows proper "two panel" installation method, using flashings and closures. This represents proper installation procedures.