View of standing seam metal roof system on medical building project in Florida, USA

View of vertical panels at roof "step up" over auditorium roof. Photos show improper "turn down" installation method. This method and installation procedure allows water infiltration into the building. Next photo shows proper "two panel" installation method, using flashings and closures. This represents proper installation procedures.
![]()